Planning Application Status



 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PL20170001326
Esperanza Place (RPUD)
Pre-Application Meeting (Status: Complete - Add Application Type)
Planned Unit Development Amendment (Status: Under Review - Closed for Uploads)
Under Review - Closed for Uploads
04/10/2017
BROOKWOOD RESIDENTIAL LLC
Proposed PUD amendment to allow group care facility for women’s transitional and emergency shelter.
Locations
Property
31345980029

Property
31345980045

Property
31345980126

Property
31345980142

Property
31345980168

Property
31345980184

Property
31345980207

Property
31345980223

Property
31345980249

Property
31345980265

Property
31345980281

Property
31345980304

Property
31345980320

Property
31345980346

Property
31345980362

Property
31345980388

Property
31345980401

Property
76040007

Property
76160000

Property
76200009

Property
76200106

Property
82967006

Property
31345980100

Application Types (Click to See Reviews)
Pre-Application Meeting
Complete - Add Application Type
Pre-Application      Status: Accepted
Planned Unit Development Amendment
Planning Commission & Board of Commissioners
Under Review - Closed for Uploads
3 Re-Submittal      Status: Accepted
Review Application Type Outcome Est. Completion Completed
Addressing - GIS Review Planned Unit Development Amendment Pending 05/25/2018
Annis Moxam ((239) 252-5519)   Send Email
Comprehensive Planning Review Planned Unit Development Amendment Approved 05/25/2018 05/11/2018
Sue Faulkner ((239) 252-5715)   Send Email
Environmental Review Planned Unit Development Amendment Pending 05/25/2018
Craig Brown ((239) 252-2548)   Send Email
Miscellaneous Corrections
Outstanding
04/27/2018

Commitments Exhibit F The calculations for the preserve provided in Exhibit F (III,B) do not match up with the total shown on the Master Plan. The master plan has 1.25 acres for native vegetation and Exhibit F shows 1.26 acres and the total to be preserved on the Master Plan total is .31 acres and Exhibit F shows .32 acres Please revise. Please revise the commitment III,B to include the total for the wetland to be preserved (.18 acres) Review 2: The reference to the 0.18 acres portion of wetland vegetation is placed in the commitment language that indicates the wetlands will be donated to a public agency or money will be donated to Conservation Collier, please clarify. This contradicts the language later in the commitment that states the wetland may be mitigated to a mitigation bank. The wetland reference should be placed in the language referring to the wetland mitigation.
Miscellaneous Corrections
Outstanding
04/27/2018

If the preserve referenced in the commitments (Exhibit F) III,B has not be executed and approved by the BOCC then the language needs to be revised to reflect current LDC requirements for offsite preserves. 3.05.07 H.1.f. iii Review 2: Exhibit F Environmental Commitments B .031 acres of the native vegetation was the preservation requirement. The 0.18 acres (wetlands) was addressed with the purchased credits from a wetland mitigation bank (0.72acres). The remaining 0.13 acres of upland was to be addressed by a donation of land off-site to a public agency or monetary donation to Conservation Collier. Please provide documentation the 0.13 acres donation has occurred. If the donation has not been provided as outlined in the PUD, staff will have to determine if the preserve will need to meet current code preserve requirement of 25%. LDC 3.05.07 (B) Please contact staff to discuss this in further detail. Craig.Brown@colliercountyfl.gov
Fire Review Planned Unit Development Amendment Approved 05/25/2018 04/30/2018
Daniel Zunzunegui ((239) 252-2309)   Send Email
School District Review Planned Unit Development Amendment Pending 05/25/2018
James Sabo ((239) 252-2708)   Send Email
Miscellaneous Corrections
Outstanding
04/27/2018

A School District Review was requested of Collier County Schools. No Review Comments were provided. However, review comments from the Collier Schools may be forthcoming.
Zoning Review Planned Unit Development Amendment Pending 05/25/2018
James Sabo ((239) 252-2708)   Send Email
County Attorney Review Planned Unit Development Amendment Rejected 05/25/2018 05/22/2018
Scott Stone ((239) 252-5740)   Send Email
Miscellaneous Corrections
Resolved
05/22/2018

See handwritten markups on PUD document, to be provided by separate e-mail from staff.
Miscellaneous Corrections
Outstanding
05/22/2018

Sent e-mail to applicant with comments and changes to PUD document. I will leave this review in "reject" until they provide a satisfactory revised PUD document.

2 Re-Submittal      Status: Returned for Correction
Review Application Type Outcome Est. Completion Completed
Addressing - GIS Review Planned Unit Development Amendment Approved 03/29/2018 03/27/2018
Annis Moxam ((239) 252-5519)   Send Email
Miscellaneous Corrections
Resolved
03/27/2018

Exhibit A - legal description need to include the Plat per Plat Book 52 Pages 3 & 4
Miscellaneous Corrections
Resolved
03/27/2018

Exhibit C - need to include street name Esperanza Way per Plat Book 52 Pages 3 & 4.
Comprehensive Planning Review Planned Unit Development Amendment Approved 03/29/2018 03/13/2018
David C. Weeks ((239) 252-2306)   Send Email
Environmental Review Planned Unit Development Amendment Rejected 03/29/2018 03/29/2018
Craig Brown ((239) 252-2548)   Send Email
Miscellaneous Corrections
Carried Forward
04/27/2018

Commitments Exhibit F The calculations for the preserve provided in Exhibit F (III,B) do not match up with the total shown on the Master Plan. The master plan has 1.25 acres for native vegetation and Exhibit F shows 1.26 acres and the total to be preserved on the Master Plan total is .31 acres and Exhibit F shows .32 acres Please revise. Please revise the commitment III,B to include the total for the wetland to be preserved (.18 acres) Review 2: The reference to the 0.18 acres portion of wetland vegetation is placed in the commitment language that indicates the wetlands will be donated to a public agency or money will be donated to Conservation Collier, please clarify. This contradicts the language later in the commitment that states the wetland may be mitigated to a mitigation bank. The wetland reference should be placed in the language referring to the wetland mitigation.
Miscellaneous Corrections
Resolved
03/27/2018

Please add a note on the Master Concept plan (Deviation 2) to indicate there are no preserves areas onsite.
Miscellaneous Corrections
Carried Forward
04/27/2018

If the preserve referenced in the commitments (Exhibit F) III,B has not be executed and approved by the BOCC then the language needs to be revised to reflect current LDC requirements for offsite preserves. 3.05.07 H.1.f. iii Review 2: Exhibit F Environmental Commitments B .031 acres of the native vegetation was the preservation requirement. The 0.18 acres (wetlands) was addressed with the purchased credits from a wetland mitigation bank (0.72acres). The remaining 0.13 acres of upland was to be addressed by a donation of land off-site to a public agency or monetary donation to Conservation Collier. Please provide documentation the 0.13 acres donation has occurred. If the donation has not been provided as outlined in the PUD, staff will have to determine if the preserve will need to meet current code preserve requirement of 25%. LDC 3.05.07 (B) Please contact staff to discuss this in further detail. Craig.Brown@colliercountyfl.gov
Fire Review Planned Unit Development Amendment Approved 03/29/2018 03/28/2018
Daniel Zunzunegui ((239) 252-2309)   Send Email
Historical Review Planned Unit Development Amendment Approved 03/29/2018 03/23/2018
Ray Bellows ((239) 252-2463)   Send Email
Miscellaneous Corrections
Resolved
03/23/2018

Indicate that the PUD is not within the Probability Area, or submit a Phase I Cultural Resource Assessment and schedule a public hearing before the HAPB.
School District Review Planned Unit Development Amendment Rejected 03/29/2018 03/29/2018
James Sabo ((239) 252-2708)   Send Email
Miscellaneous Corrections
Carried Forward
04/27/2018

A School District Review was requested of Collier County Schools. No Review Comments were provided. However, review comments from the Collier Schools may be forthcoming.
Transportation Planning Review Planned Unit Development Amendment Approved 03/29/2018 03/29/2018
Michael Sawyer ((239) 252-2926)   Send Email
Res. 06-299. TIS Guidelines
Resolved
03/29/2018

TIS Guidelines (Resolution 06-299) Rev.1: Please provide requested TIS. See pre app meeting notes and check-off methodology-TIS required. Review comments will be provided when the TIS is provided.
Miscellaneous Corrections
Resolved
03/29/2018

Miscellaneous Corrections Rev.1: Note that the "Traffic Comparison" letter provided appears to indicate the following: A. An increase of 13 additional single family dwelling units. B. A reduction of 72 fewer apartment dwelling units. c. An increase of 45 new group housing units to be calculated using ITE 220 Apartment rate. The letter also appears to confuse/mix the proposed 96 apartment units with multi-family which are separate ITE calculated uses/dwelling types. Please recheck the above, make needed corrections and complete the TIS for the next submittal.
Developer Commitments
Resolved
03/29/2018

Developer commitments made as a condition of zoning are not adequately addressed Rev.1: Please provide standard PUD monitoring single entity commitment. "One entity (hereinafter the Managing Entity) shall be responsible for PUD monitoring until close-out of the PUD, and this entity shall also be responsible for satisfying all PUD commitments until close-out of the PUD. At the time of this PUD approval, the Managing Entity is XXXXX. Should the Managing Entity desire to transfer the monitoring and commitments to a successor entity, then it must provide a copy of a legally binding document that needs to be approved for legal sufficiency by the County Attorney. After such approval, the Managing Entity will be released of its obligations upon written approval of the transfer by County staff, and the successor entity shall become the Managing Entity. As Owner and Developer sell off tracts, the Managing Entity shall provide written notice to County that includes an acknowledgement of the commitments required by the PUD by the new owner and the new owner’s agreement to comply with the Commitments through the Managing Entity, but the Managing Entity shall not be relieved of its responsibility under this Section. When the PUD is closed-out, then the Managing Entity is no longer responsible for the monitoring and fulfillment of PUD commitments."
Developer Commitments
Resolved
03/29/2018

Developer commitments made as a condition of zoning are not adequately addressed Rev.1: Please provide trip limit commitment consistent with the requested-required TIS. Please also include as part of the commitment...….”based on the use codes in the ITE Manual on trip generation rates in effect at the time of application for SDP/SDPA or subdivision plat approval.”
Zoning Review Planned Unit Development Amendment Approved 03/29/2018 03/28/2018
James Sabo ((239) 252-2708)   Send Email
Miscellaneous Corrections
Resolved
03/28/2018

Affordable Housing Density Bonus, Insufficient, Cormac Giblin the Housing and Grant Development Manager has reviewed the proposed amendments to the Affordable Housing Density Bonus Agreement and the cross through and underline calculations are correct. However, please submit a clean copy (non-handwritten) version with updated County Office addresses and the new Commission Chairman for approval by the CCPC and BCC.
Miscellaneous Corrections
Resolved
03/28/2018

PUD Master Plan Document, Insufficient, the narrative statement indicates 159 conventional dwelling units and 45 emergency group housing units. The exhibit C. Master Plan document indicates 139 dwelling units. Please revise the Master Plan document so that the number of dwelling units in the narrative statement and the Master Plan are consistent.
Miscellaneous Corrections
Resolved
03/28/2018

PUD Master Plan Document, Insufficient, the proposed group housing component is described as internally gated. The exhibit C. Master Plan document does not indicate a general area for the location of the group housing. Please revise the Master Plan document to indicate the general location for the proposed group housing.
Miscellaneous Corrections
Resolved
03/28/2018

PUD Master Plan Document, Insufficient, pursuant to LDC subsection 10.02.13 B(1)(d), the proposed group housing appears to be compatible with the existing adjacent residential uses and current neighborhood conditions. However, the proposed 8-foot perimeter wall around the group housing on Tract A does not appear to be a compatible use with respect to an architectural feature as there is no landscape material proposed in the narrative statement. Please provide additional justification for proposed wall height deviation and information for additional landscape material that will mitigate the visual effect of the requested deviation for fence/wall height.
County Attorney Review Planned Unit Development Amendment Rejected 03/29/2018 03/29/2018
Scott Stone ((239) 252-5740)   Send Email
Miscellaneous Corrections
Resolved
03/29/2018

If you're proposing to revise the Affordable Housng Agreement, then you'll need to provide a digital strikethrough/underline version--not handwritten markups. Also, please make sure that County Housing staff are aware of your proposed changes to the Agreement, and that they are reviewing it in conjunction with this PUDA request.
Miscellaneous Corrections
Resolved
03/29/2018

Please provide a copy of the approved Amended Housing Agreement once reviewed and approved by staff and the County Attorney's office.
Miscellaneous Corrections
Resolved
03/29/2018

Please confirm that Brookwood Residential, LLC owns 100% of the PUD property.
Miscellaneous Corrections
Resolved
03/29/2018

Please clarify what type of "group housing" uses you are proposing. Provide specific examples.
Miscellaneous Corrections
Resolved
03/29/2018

Please confirm that a maximum of 45 group housing units would not exceed the maximum 0.45 FAR permitted for group housing uses.
Miscellaneous Corrections
Resolved
03/29/2018

Please explain what you are revising on the Master PLan.
Miscellaneous Corrections
Carried Forward
04/27/2018

See handwritten markups on PUD document, to be provided by separate e-mail from staff.
Landscape Review Planned Unit Development Amendment Approved 03/29/2018 03/21/2018
Mark Templeton ((239) 252-2475)   Send Email
4.06.02 Perimeter landscape buffers
Resolved
03/21/2018

4.06.02. Provide perimeter landscape buffers. See also LDC section 4.06.02 C, Table 2.4. Please call out the width of the buffer along Immokallee Dr. For developments over 15 acres, Type 'D' buffers are required to be 20'.
Miscellaneous Corrections
Resolved
03/21/2018

Please specify the dwelling type for tract B to ensure that the buffers identified adjacent to this tract are correct.

1 Initial Submittal      Status: Returned for Correction
Review Application Type Outcome Est. Completion Completed
Addressing - GIS Review Planned Unit Development Amendment Rejected 12/08/2017 12/04/2017
Annis Moxam ((239) 252-5519)   Send Email
Miscellaneous Corrections
Carried Forward
03/01/2018

Exhibit A - legal description need to include the Plat per Plat Book 52 Pages 3 & 4
Miscellaneous Corrections
Carried Forward
03/01/2018

Exhibit C - need to include street name Esperanza Way per Plat Book 52 Pages 3 & 4.
Comprehensive Planning Review Planned Unit Development Amendment Approved 12/08/2017 12/08/2017
Sue Faulkner ((239) 252-5715)   Send Email
Emergency Management Review Planned Unit Development Amendment Approved 12/08/2017 12/14/2017
Dan Summers ((239) 252-8000)   Send Email
Engineering Stormwater Review Planned Unit Development Amendment Approved 12/08/2017 11/28/2017
Richard Orth ((239) 252-5092)   Send Email
Environmental Review Planned Unit Development Amendment Rejected 12/08/2017 12/08/2017
Craig Brown ((239) 252-2548)   Send Email
Miscellaneous Corrections
Carried Forward
03/01/2018

Commitments Exhibit F The calculations for the preserve provided in Exhibit F (III,B) do not match up with the total shown on the Master Plan. The master plan has 1.25 acres for native vegetation and Exhibit F shows 1.26 acres and the total to be preserved on the Master Plan total is .31 acres and Exhibit F shows .32 acres Please revise. Please revise the commitment III,B to include the total for the wetland to be preserved (.18 acres)
Miscellaneous Corrections
Carried Forward
03/01/2018

Please add a note on the Master Concept plan (Deviation 2) to indicate there are no preserves areas onsite.
Miscellaneous Corrections
Carried Forward
03/01/2018

If the preserve referenced in the commitments (Exhibit F) III,B has not be excuted and approved by the BOCC then the language needs to be revised to reflect current LDC requirements for offsite preserves. 3.05.07 H.1.f. iii
Fire Review Planned Unit Development Amendment Approved 12/08/2017 12/08/2017
Daniel Zunzunegui ((239) 252-2309)   Send Email
Graphics - GIS Review Planned Unit Development Amendment Approved 12/08/2017 11/15/2017
Beth Yang ((239) 252-6208)   Send Email
Historical Review Planned Unit Development Amendment Rejected 12/08/2017 11/14/2017
LEGACY: Fred Reischl ((239) 252-4211)   Send Email
Miscellaneous Corrections
Carried Forward
03/01/2018

Indicate that the PUD is not within the Probability Area, or submit a Phase I Cultural Resource Assessment and schedule a public hearing before the HAPB.
Parks and Rec Review Planned Unit Development Amendment Approved 12/08/2017 11/30/2017
David Berra   Send Email
School District Review Planned Unit Development Amendment Rejected 12/08/2017 12/15/2017
James Sabo ((239) 252-2708)   Send Email
Miscellaneous Corrections
Carried Forward
03/01/2018

A School District Review was requested of Collier County Schools. No Review Comments were provided. However, review comments from the Collier Schools may be forthcoming.
Transportation Pathways Review Planned Unit Development Amendment Approved 12/08/2017 12/07/2017
Michael Sawyer ((239) 252-2926)   Send Email
Transportation Planning Review Planned Unit Development Amendment Rejected 12/08/2017 12/07/2017
Michael Sawyer ((239) 252-2926)   Send Email
Res. 06-299. TIS Guidelines
Carried Forward
03/01/2018

TIS Guidelines (Resolution 06-299) Rev.1: Please provide requested TIS. See pre app meeting notes and check-off methodology-TIS required. Review comments will be provided when the TIS is provided.
Miscellaneous Corrections
Carried Forward
03/01/2018

Miscellaneous Corrections Rev.1: Note that the "Traffic Comparison" letter provided appears to indicate the following: A. An increase of 13 additional single family dwelling units. B. A reduction of 72 fewer apartment dwelling units. c. An increase of 45 new group housing units to be calculated using ITE 220 Apartment rate. The letter also appears to confuse/mix the proposed 96 apartment units with multi-family which are separate ITE calculated uses/dwelling types. Please recheck the above, make needed corrections and complete the TIS for the next submittal.
Developer Commitments
Carried Forward
03/01/2018

Developer commitments made as a condition of zoning are not adequately addressed Rev.1: Please provide standard PUD monitoring single entity commitment. "One entity (hereinafter the Managing Entity) shall be responsible for PUD monitoring until close-out of the PUD, and this entity shall also be responsible for satisfying all PUD commitments until close-out of the PUD. At the time of this PUD approval, the Managing Entity is XXXXX. Should the Managing Entity desire to transfer the monitoring and commitments to a successor entity, then it must provide a copy of a legally binding document that needs to be approved for legal sufficiency by the County Attorney. After such approval, the Managing Entity will be released of its obligations upon written approval of the transfer by County staff, and the successor entity shall become the Managing Entity. As Owner and Developer sell off tracts, the Managing Entity shall provide written notice to County that includes an acknowledgement of the commitments required by the PUD by the new owner and the new owner’s agreement to comply with the Commitments through the Managing Entity, but the Managing Entity shall not be relieved of its responsibility under this Section. When the PUD is closed-out, then the Managing Entity is no longer responsible for the monitoring and fulfillment of PUD commitments."
Developer Commitments
Carried Forward
03/01/2018

Developer commitments made as a condition of zoning are not adequately addressed Rev.1: Please provide trip limit commitment consistent with the requested-required TIS. Please also include as part of the commitment...….”based on the use codes in the ITE Manual on trip generation rates in effect at the time of application for SDP/SDPA or subdivision plat approval.”
Zoning Review Planned Unit Development Amendment Rejected 12/08/2017 12/15/2017
James Sabo ((239) 252-2708)   Send Email
Miscellaneous Corrections
Carried Forward
03/01/2018

Affordable Housing Density Bonus, Insufficient, Cormac Giblin the Housing and Grant Development Manager has reviewed the proposed amendments to the Affordable Housing Density Bonus Agreement and the cross through and underline calculations are correct. However, please submit a clean copy (non-handwritten) version with updated County Office addresses and the new Commission Chairman for approval by the CCPC and BCC.
Miscellaneous Corrections
Carried Forward
03/01/2018

PUD Master Plan Document, Insufficient, the narrative statement indicates 159 conventional dwelling units and 45 emergency group housing units. The exhibit C. Master Plan document indicates 139 dwelling units. Please revise the Master Plan document so that the number of dwelling units in the narrative statement and the Master Plan are consistent.
Miscellaneous Corrections
Carried Forward
03/01/2018

PUD Master Plan Document, Insufficient, the proposed group housing component is described as internally gated. The exhibit C. Master Plan document does not indicate a general area for the location of the group housing. Please revise the Master Plan document to indicate the general location for the proposed group housing.
Miscellaneous Corrections
Carried Forward
03/01/2018

PUD Master Plan Document, Insufficient, pursuant to LDC subsection 10.02.13 B(1)(d), the proposed group housing appears to be compatible with the existing adjacent residential uses and current neighborhood conditions. However, the proposed 8-foot perimeter wall around the group housing on Tract A does not appear to be a compatible use with respect to an architectural feature as there is no landscape material proposed in the narrative statement. Please provide additional justification for proposed wall height deviation and information for additional landscape material that will mitigate the visual effect of the requested deviation for fence/wall height.
County Attorney Review Planned Unit Development Amendment Rejected 12/08/2017 12/08/2017
Scott Stone ((239) 252-5740)   Send Email
Miscellaneous Corrections
Carried Forward
03/01/2018

If you're proposing to revise the Affordable Housng Agreement, then you'll need to provide a digital strikethrough/underline version--not handwritten markups. Also, please make sure that County Housing staff are aware of your proposed changes to the Agreement, and that they are reviewing it in conjunction with this PUDA request.
Miscellaneous Corrections
Carried Forward
03/01/2018

Please provide a copy of the approved Amended Housing Agreement once reviewed and approved by staff and the County Attorney's office.
Miscellaneous Corrections
Carried Forward
03/01/2018

Please confirm that Brookwood Residential, LLC owns 100% of the PUD property.
Miscellaneous Corrections
Carried Forward
03/01/2018

Please clarify what type of "group housing" uses you are proposing. Provide specific examples.
Miscellaneous Corrections
Carried Forward
03/01/2018

Please confirm that a maximum of 45 group housing units would not exceed the maximum 0.45 FAR permitted for group housing uses.
Miscellaneous Corrections
Carried Forward
03/01/2018

Please explain what you are revising on the Master PLan.
Miscellaneous Corrections
Carried Forward
03/01/2018

Miscellaneous Corrections
Landscape Review Planned Unit Development Amendment Rejected 12/08/2017 12/07/2017
Mark Templeton ((239) 252-2475)   Send Email
4.06.02 Perimeter landscape buffers
Carried Forward
03/01/2018

4.06.02. Provide perimeter landscape buffers. See also LDC section 4.06.02 C, Table 2.4. Please call out the width of the buffer along Immokallee Dr. For developments over 15 acres, Type 'D' buffers are required to be 20'.
Miscellaneous Corrections
Carried Forward
03/01/2018

Please specify the dwelling type for tract B to ensure that the buffers identified adjacent to this tract are correct.
GIS Review Planned Unit Development Amendment Approved 12/08/2017 12/04/2017
William Fowler   Send Email

Fees
Paid Fees Amount Paid Owing Date Paid
Pre-application Meeting $500.00 $500.00 Paid 04/25/2017
Pre-application Meeting $0.00 $0.00 Paid 04/26/2017
Comp Planning Review - PUDA $2,250.00 $2,250.00 Paid 11/07/2017
Planned Unit Development Amendment $6,000.00 $6,000.00 Paid 11/07/2017
Site Area (Acreage) fee $0.00 $0.00 $0.00 N/A
Fire Code Review - PUDA $125.00 $125.00 Paid 11/07/2017
Legal Advertising Fee $1,125.00 $1,125.00 Paid 11/07/2017
Legal Advertising Fee (BCC) $500.00 $500.00 Paid 11/07/2017
TIS Methodology Review $500.00 $500.00 Paid 11/07/2017
Graphics Property Notification Address Listing $85.00 $85.00 Paid 12/08/2017
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


Your project will not be reviewed until all fees are paid in full.

Deposits & Bonds

There are no deposits or bonds for this planning application.

Inspections

There are no inspections for this planning application.

Documents & Images
Date Uploaded Document Name
04/25/2017 Receipt for transaction: 2017-025657
04/26/2017 Pre-App Meeting Notes
10/31/2017 Submittal 1 - Addressing Checklist
11/29/2017 Affidavit of Authorization/Evidence of Authority (Submittal 1 Affidavit of Authorization - Prepared.pdf)
11/09/2017 Aerial Photographs (Submittal 1 Aerial - Prepared.pdf)
10/31/2017 Submittal 1 - Covenant Unified Control
11/07/2017 Application Form (Submittal 1 Application PUDA - Prepared.pdf)
11/07/2017 Cover Letter/Narrative Statement (Submittal 1 CoverLtr-PUDA 2017 - Prepared.pdf)
10/31/2017 Submittal 1 - Density Bonus Agreement - 2008
05/21/2018 Deviation Request (Submittal 3 Deviation Justifications-v2 - Prepared.pdf)
02/28/2018 Submittal 2 - Density Bonus Agreement
11/29/2017 Exhibits A-F (Submittal 1 Exh 2 EvaluationCriteria - Prepared.pdf)
11/14/2017 Property Owners List (Submittal 1 Exh 1 Parcel ID List - Prepared.pdf)
03/26/2018 Legal Desciption and Legal Sketch of Subject Area (Submittal 2 Exh A-Legal Description-v1 - Prepared.pdf)
03/13/2018 Exhibits A-F (Submittal 2 Exh C MCP 2017 - Prepared.pdf)
10/31/2017 Submittal 1 - Ordinance 2008-28
03/21/2018 Exhibits A-F (Submittal 2 Proposed Exh A-F 01-2018 - Prepared.pdf)
10/31/2017 Submittal 1 - Pre-app Notes
10/31/2017 Submittal 1 - Statement Utility Provisions
10/31/2017 Submittal 1 - Warranty Deeds
03/29/2018 Traffic Analysis (Submittal 2 Traffic Impact Statement 2-28-2018 - Prepared.pdf)
11/02/2017 PL Payment Slip
11/07/2017 Receipt for transaction: 2017-071270
11/07/2017 RLS
12/07/2017 PL Payment Slip
12/08/2017 Receipt for transaction: 2017-079014
12/08/2017 Comp Planning Consistency Review1.pdf
12/15/2017 Review Comment Letter
04/26/2018 Submittal 3 - Response Letter
02/28/2018 SUbmittal 2 - Environmental Impact Statement
02/28/2018 Submittal 2 - Historical Archeological Survey (Waiver)
02/28/2018 Submittal 2 - Environmental Data Requirements (Env - Mitigation Receipt)
02/28/2018 Submittal 2 - Collier Receipt SDP Fees
02/28/2018 Submittal 2 - Env - Esperanza 5-7-08 EAC meeting memo
03/01/2018 Submittal 2 - RLS
03/13/2018 PUDA-PL2017-1326 Esperanza Place RPUD R2.docx
03/30/2018 Review Comment Letter
04/26/2018 Submittal 3 - Revised PUD Documents
04/26/2018 Submittal 3 - Copy of Mitigation (Env-Off-site Mitigation)
04/27/2018 Submittal 3 - RLS
05/11/2018 Comp Planning Consistency Review2.pdf
05/11/2018 Comp Planning Consistency Review3.pdf
Submittals | Portal Home
Powered by CityView